SINAMICS G120X Rated power: 4 kW At 110% 60s, 100% 240 s Radio interference suppression filter for category C2 380-480 V 3 AC +10/-20% 47-63 Hz Ambient temperature -20 to +45 °C Size: FSB Degree of protection IP20 / UL open type The SINAMICS G120X frequency converter masters the elements for the pump/fan applications, the water/wastewater (W/WW) and building technology/HVAC sectors. The SINAMICS G120X impresses due to the straightforward selection and ordering, easy handling out of the box and simple integration in the application. Simple setup with the SINAMICS G120 Smart Access Module or the IOP-2 operator panel. The SINAMICS G120X operates stably under all line conditions, optionally complies with the EMC categories C2 and C1, and is particularly robust due to its operating temperature from -20 °C to +60 °C. Specific industry functions such as tube filling mode and bypass function make the converter especially efficient. All devices of the series are harmonized and integrated in terms of their voltages and networks, as well as consistently designed for cost-optimized and resource-saving operation. Their compact design saves space in the control cabinet. The SINAMICS G120X is available in nine frame sizes in a performance range between 0.75 kW and 630 kW. In addition, this variant contains DC terminals for the connection of du/dt filters. The SINAMICS G120X frequency converter can be put into operation easily using various options such as the external Basic Operator Panel (BOP-2), the Smart Access Module (SAM) and the Intelligent Operator Panel (IOP-2). SINAMICS – simply my drive.
| |
Width: | 100.000 mm |
Height: | 275.000 mm |
Depth: | 209.000 mm |
Number of digital inputs: | 6.000 |
Number of analogue inputs: | 2.000 |
Number of analogue outputs: | 1.000 |
Supporting protocol for LON: | false |
Number of HW-interfaces industrial Ethernet: | 2.000 |
Number of HW-interfaces RS-232: | 1.000 |
Number of HW-interfaces RS-422: | 0.000 |
Number of HW-interfaces RS-485: | 0.000 |
Number of HW-interfaces serial TTY: | 5.000 |
Number of HW-interfaces USB: | 0.000 |
Number of HW-interfaces parallel: | 0.000 |
Number of HW-interfaces other: | 6.000 |
With optical interface: | false |
Supporting protocol for TCP/IP: | true |
Supporting protocol for ASI: | false |
Supporting protocol for PROFIBUS: | false |
Supporting protocol for CAN: | false |
Supporting protocol for INTERBUS: | false |
Supporting protocol for KNX: | false |
Supporting protocol for Modbus: | false |
Supporting protocol for Data-Highway: | false |
Supporting protocol for DeviceNet: | false |
Supporting protocol for SUCONET: | false |
Supporting protocol for other bus systems: | false |
Degree of protection (IP): | IP20 |
With PC connection: | false |
Supporting protocol for SERCOS: | false |
Supporting protocol for INTERBUS-Safety: | false |
Mains voltage: | 380.000 V | 480.000 V |
4-quadrant operation possible: | false |
Number of interfaces PROFINET: | 2.000 |
Type of converter: | U converter |
Number of phases output: | 3 |
Number of phases input: | 3 |
Integrated breaking resistance: | false |
Application in industrial area permitted: | true |
Application in domestic- and commercial area permitted: | false |
Max. output frequency: | 550.000 Hz |
Max. output at linear load at rated output voltage: | 3.000 kW |
Max. output at quadratic load at rated output voltage: | 4.000 kW |
Relative symmetric net voltage tolerance: | -20.000 % |
Relative symmetric net frequency tolerance: | 5.000 % |
Supporting protocol for AS-Interface Safety at Work: | false |
Supporting protocol for DeviceNet Safety: | false |
Supporting protocol for EtherNet/IP: | true |
Supporting protocol for Foundation Fieldbus: | false |
Supporting protocol for PROFINET CBA: | false |
Supporting protocol for PROFINET IO: | false |
Supporting protocol for PROFIsafe: | false |
Supporting protocol for SafetyBUS p: | false |
Nominal output current I2N: | 10.500 A |