ASIsafe SlimLine module S22.5F Phased-out product !!! For further information, please contact our sales department digital safety, 2 F-DI/2 DQ, IP20 2 x input for mechanical sensors 2 x standard output 24 V DC Output supply from 24 V DC Screw terminals Overall width 22.5 mm
| |
Width: | 22.500 mm |
Height: | 101.600 mm |
Depth: | 91.000 mm |
Input current at signal 1: | 5.000 mA |
Number of digital outputs: | 2.000 |
Voltage type of supply voltage: | DC |
Supporting protocol for LON: | false |
Number of HW-interfaces industrial Ethernet: | 0.000 |
Number of HW-interfaces RS-232: | 0.000 |
Number of HW-interfaces RS-422: | 0.000 |
Number of HW-interfaces RS-485: | 0.000 |
Number of HW-interfaces serial TTY: | 0.000 |
Number of HW-interfaces USB: | 0.000 |
Number of HW-interfaces parallel: | 0.000 |
Number of HW-interfaces other: | 0.000 |
With optical interface: | false |
Type of voltage (input voltage): | DC |
Supporting protocol for TCP/IP: | false |
Supporting protocol for ASI: | true |
Supporting protocol for PROFIBUS: | false |
Supporting protocol for CAN: | false |
Supporting protocol for INTERBUS: | false |
Supporting protocol for KNX: | false |
Supporting protocol for Modbus: | false |
Supporting protocol for Data-Highway: | false |
Supporting protocol for DeviceNet: | false |
Supporting protocol for SUCONET: | false |
Supporting protocol for other bus systems: | false |
Short-circuit protection, outputs available: | true |
Type of electric connection: | Screw connection |
Rail mounting possible: | false |
Explosion safety category for gas: | None |
System accessory: | true |
Appendant operation agent (Ex ia): | false |
Appendant operation agent (Ex ib): | false |
Degree of protection (IP): | IP20 |
Supporting protocol for SERCOS: | false |
Supporting protocol for INTERBUS-Safety: | false |
Number of interfaces PROFINET: | 0.000 |
Number of HW-interfaces Wireless: | 0.000 |
Front built-in possible: | false |
Rack-assembly possible: | false |
Wall mounting/direct mounting: | false |
Radio standard Bluetooth: | false |
Radio standard Wi-Fi 802.11: | false |
IO link master: | false |
Performance level according to EN ISO 13849-1: | Level e |
Supporting protocol for AS-Interface Safety at Work: | true |
Supporting protocol for DeviceNet Safety: | false |
Supporting protocol for EtherNet/IP: | false |
Supporting protocol for Foundation Fieldbus: | false |
Supporting protocol for PROFINET CBA: | false |
Supporting protocol for PROFINET IO: | false |
Supporting protocol for PROFIsafe: | false |
Supporting protocol for SafetyBUS p: | false |
Type of output voltage: | DC |
Digital outputs configurable: | false |
Radio standard GPRS: | false |
Radio standard GSM: | false |
Radio standard UMTS: | false |
SIL according to IEC 61508: | 3 |