TeSys - Analoge I/O-module - 2 analoge ingangen - 1 analoge uitgang. In verbinding met een TPRBC-buskoppelaar wordt deze gebruikt voor geavanceerde besturingsfuncties (TeSys-avatars). Er kunnen twee analoge ingangen worden geconfigureerd voor het meten van spanning (-10/+10V, 0/+10V), stroom (0-20mA, 4-20mA) of temperatuursondes (Ni, Pt, thermokoppels). Eén analoge uitgang kan worden geconfigureerd voor de sturingsspanningsbron (-10/+10V, 0/+10V) of stroombron (0-20mA, 4-20mA). Montage op DIN-rail samen met de andere modules van de TeSys Island-configuratie. Multi-standaarden gecertificeerd (IEC, UL, CSA, CCC, EAC), Green Premium-conform (RoHS/REACh).
| |
Width: | 25.000 mm |
Height: | 118.000 mm |
Depth: | 114.000 mm |
Suitable for safety functions: | false |
Number of analogue inputs: | 2.000 |
Number of analogue outputs: | 1.000 |
Voltage type of supply voltage: | DC |
Supporting protocol for LON: | false |
Number of HW-interfaces industrial Ethernet: | 0.000 |
Number of HW-interfaces RS-232: | 0.000 |
Number of HW-interfaces RS-422: | 0.000 |
Number of HW-interfaces RS-485: | 0.000 |
Number of HW-interfaces serial TTY: | 0.000 |
Number of HW-interfaces USB: | 0.000 |
Number of HW-interfaces parallel: | 0.000 |
Number of HW-interfaces other: | 2.000 |
Supporting protocol for TCP/IP: | false |
Supporting protocol for ASI: | false |
Supporting protocol for PROFIBUS: | false |
Supporting protocol for CAN: | false |
Supporting protocol for INTERBUS: | false |
Supporting protocol for KNX: | false |
Supporting protocol for Modbus: | false |
Supporting protocol for Data-Highway: | false |
Supporting protocol for DeviceNet: | false |
Supporting protocol for SUCONET: | false |
Supporting protocol for other bus systems: | true |
Input, current: | true |
Input, voltage: | true |
Input, resistor: | false |
Input, resistance thermometer: | true |
Input, thermocouple: | true |
Input signal, configurable: | true |
Output, current: | true |
Output, voltage: | true |
Output signal configurable: | true |
Resolution of the analogue inputs: | 16.000 Bit |
Resolution of the analogue outputs: | 12.000 Bit |
Type of electric connection: | Plug-in connection |
Rail mounting possible: | true |
Explosion safety category for gas: | None |
Explosion safety category for dust: | None |
Fieldbus connection over separate bus coupler possible: | true |
System accessory: | true |
Appendant operation agent (Ex ia): | false |
Appendant operation agent (Ex ib): | false |
Degree of protection (IP): | IP20 |
Supporting protocol for SERCOS: | false |
Supporting protocol for INTERBUS-Safety: | false |
Number of interfaces PROFINET: | 0.000 |
Number of HW-interfaces Wireless: | 0.000 |
Front built-in possible: | false |
Rack-assembly possible: | false |
Wall mounting/direct mounting: | false |
Radio standard Bluetooth: | false |
Radio standard Wi-Fi 802.11: | false |
IO link master: | false |
Performance level according to EN ISO 13849-1: | None |
Supporting protocol for AS-Interface Safety at Work: | false |
Supporting protocol for DeviceNet Safety: | false |
Supporting protocol for EtherNet/IP: | false |
Supporting protocol for Foundation Fieldbus: | false |
Supporting protocol for PROFINET CBA: | false |
Supporting protocol for PROFINET IO: | false |
Supporting protocol for PROFIsafe: | false |
Supporting protocol for SafetyBUS p: | false |
Supply voltage DC: | 20.400 V | 28.800 V |
Analogue inputs configurable: | true |
Analogue outputs configurable: | true |
Radio standard GPRS: | false |
Radio standard GSM: | false |
Radio standard UMTS: | false |
SIL according to IEC 61508: | None |