Separation amplifier 24 V AC/DC, 3-way separation input: 0-20 mA output: 0-20 mA Spring-type terminal (push-in) galvanic isolation plate is available as well as various connecting combs.The 3RS70 signal converters replace the well-proven 3RS17 series.SIRIUS relays - one range for every application.
| |
Width: | 6.200 mm |
Height: | 93.000 mm |
Depth: | 72.500 mm |
Number of channels: | 1.000 |
Power consumption: | 0.290 W |
Operating temperature: | -25.000 °C | 60.000 °C |
Type of electric connection: | Spring clamp connection |
Degree of protection (IP): | IP20 |
Number of output ranges +10 V ... -10 V: | 0.000 |
Number of output ranges +5 V ... -5 V: | 0.000 |
Number of output ranges 0 V ... 1 V: | 0.000 |
Number of output ranges 0 mA ... 10 mA: | 0.000 |
Number of output ranges 0 mV ... 100 mV: | 0.000 |
Number of output ranges 0 V ... 2 V: | 0.000 |
Number of output ranges 0 V ... 2.5 V: | 0.000 |
Number of output ranges 0 V ... 20 V: | 0.000 |
Number of output ranges 0 mV ... 200 mV: | 0.000 |
Number of output ranges 0 V ... 24 V: | 0.000 |
Number of output ranges 0 V ... 30 V: | 0.000 |
Number of output ranges 0 mV ... 300 mV: | 0.000 |
Number of output ranges 0 mA ... 5 mA: | 0.000 |
Number of output ranges 0 V ... 5 V: | 0.000 |
Number of output ranges 0 mV ... 500 mV: | 0.000 |
Number of output ranges 0 mV ... 60 mV: | 0.000 |
Number of output ranges -1 V ... +1 V: | 0.000 |
Number of output ranges 1 V ... 5 V: | 0.000 |
Number of output ranges -10 mA ... +10 mA: | 0.000 |
Number of output ranges -10 V ... +10 V: | 0.000 |
Number of output ranges 10 V ... 0 V: | 0.000 |
Number of output ranges 10 V ... 2 V: | 0.000 |
Number of output ranges -100 mV ... +100 mV: | 0.000 |
Number of output ranges -2 V ... +2 V: | 0.000 |
Number of output ranges 2 V ... 10 V: | 0.000 |
Number of output ranges -2.5 V ... +2.5 V: | 0.000 |
Number of output ranges -20 mA ... +20 mA: | 0.000 |
Number of output ranges -20 V ... +20 V: | 0.000 |
Number of output ranges 20 mA ... 0 mA: | 0.000 |
Number of output ranges 20 mA ... 4 mA: | 0.000 |
Number of output ranges -300 mV ... +300 mV: | 0.000 |
Number of output ranges -5 mA ... +5 mA: | 0.000 |
Number of output ranges -5 V ... +5 V: | 0.000 |
Number of output ranges 5 V ... 0 V: | 0.000 |
Number of output ranges 5 V ... 1 V: | 0.000 |
Number of output ranges -500 mV ... +500 mV: | 0.000 |
Number of output ranges -60 mV ... +60 mV: | 0.000 |
Number of input ranges +10 V ... -10 V: | 0.000 |
Number of input ranges +5 V ... -5 V: | 0.000 |
Number of input ranges 0 V ... 2.5 V: | 0.000 |
Number of input ranges 0 mV ... 200 mV: | 0.000 |
Number of input ranges 0 V ... 24 V: | 0.000 |
Number of input ranges 0 V ... 30 V: | 0.000 |
Number of input ranges -1 V ... +1 V: | 0.000 |
Number of input ranges 1 V ... 5 V: | 0.000 |
Number of input ranges -10 mA ... +10 mA: | 0.000 |
Number of input ranges -10 V ... +10 V: | 0.000 |
Number of input ranges 10 V ... 0 V: | 0.000 |
Number of input ranges 10 V ... 2 V: | 0.000 |
Number of input ranges -100 mV ... +100 mV: | 0.000 |
Number of input ranges -2 V ... +2 V: | 0.000 |
Number of input ranges -2.5 V ... +2.5 V: | 0.000 |
Number of input ranges -20 V ... +20 V: | 0.000 |
Number of input ranges 20 mA ... 0 mA: | 0.000 |
Number of input ranges 20 mA ... 4 mA: | 0.000 |
Number of input ranges -300 mV ... +300 mV: | 0.000 |
Number of input ranges -5 V ... +5 V: | 0.000 |
Number of input ranges 5 V ... 0 V: | 0.000 |
Number of input ranges 5 V ... 1 V: | 0.000 |
Number of input ranges -500 mV ... +500 mV: | 0.000 |
Number of input ranges -60 mV ... +60 mV: | 0.000 |
Rated operation frequency: | 50.000 Hz | 60.000 Hz |
Load: | 500.000 Ohm |
Load influence: | 0.000 %/100% |
Galvanic separation between output to output: | false |
Galvanic separation between input and output: | true |
Galvanic separation between inputs: | false |
Galvanic separation between supply voltage and all other current circuits: | true |
Malfunction message output: | false |
Temperature drift: | 0.015 %/K |
SIL according to IEC 61508: | None |