Width: | 107.000 mm |
Height: | 231.000 mm |
Depth: | 186.000 mm |
With control element: | true |
Number of digital inputs: | 5.000 |
Number of digital outputs: | 2.000 |
Number of analogue inputs: | 2.000 |
Number of analogue outputs: | 2.000 |
Supporting protocol for LON: | false |
Number of HW-interfaces industrial Ethernet: | 0.000 |
Number of HW-interfaces RS-232: | 0.000 |
Number of HW-interfaces RS-422: | 0.000 |
Number of HW-interfaces RS-485: | 1.000 |
Number of HW-interfaces serial TTY: | 0.000 |
Number of HW-interfaces USB: | 0.000 |
Number of HW-interfaces parallel: | 0.000 |
Number of HW-interfaces other: | 0.000 |
With optical interface: | false |
Supporting protocol for TCP/IP: | true |
Supporting protocol for ASI: | false |
Supporting protocol for PROFIBUS: | true |
Supporting protocol for CAN: | true |
Supporting protocol for INTERBUS: | false |
Supporting protocol for KNX: | false |
Supporting protocol for Modbus: | true |
Supporting protocol for Data-Highway: | false |
Supporting protocol for DeviceNet: | true |
Supporting protocol for SUCONET: | false |
Supporting protocol for other bus systems: | true |
Degree of protection (IP): | IP20 |
With PC connection: | true |
Supporting protocol for SERCOS: | false |
Supporting protocol for INTERBUS-Safety: | false |
Mains voltage: | 380.000 V | 480.000 V |
Mains frequency: | 50/60 Hz |
4-quadrant operation possible: | true |
Number of interfaces PROFINET: | 0.000 |
Type of converter: | U converter |
Number of phases output: | 3 |
Number of phases input: | 3 |
Integrated breaking resistance: | true |
Application in industrial area permitted: | true |
Application in domestic- and commercial area permitted: | true |
Max. output frequency: | 500.000 Hz |
Max. output at linear load at rated output voltage: | 1.500 kW |
Max. output at quadratic load at rated output voltage: | 1.500 kW |
Relative symmetric net voltage tolerance: | 10.000 % |
Relative symmetric net frequency tolerance: | 10.000 % |
Supporting protocol for AS-Interface Safety at Work: | false |
Supporting protocol for DeviceNet Safety: | false |
Supporting protocol for EtherNet/IP: | true |
Supporting protocol for Foundation Fieldbus: | false |
Supporting protocol for PROFINET CBA: | false |
Supporting protocol for PROFINET IO: | true |
Supporting protocol for PROFIsafe: | false |
Supporting protocol for SafetyBUS p: | false |
Max. output voltage: | 500.000 V |
Nominal output current I2N: | 4.100 A |
Supporting protocol for BACnet: | false |
Degree of protection (NEMA): | Other |