Width: | 45.000 mm |
Height: | 180.000 mm |
Depth: | 95.000 mm |
With transformer: | false |
Rated operation power at AC-3, 400 V: | 0.090 kW |
Number of command positions: | 0.000 |
Number of auxiliary contacts as normally open contact: | 1.000 |
Number of auxiliary contacts as normally closed contact: | 0.000 |
Suitable for emergency stop: | false |
Rated operation current Ie: | 0.310 A |
Number of indicator lights: | 0.000 |
Overload release current setting: | 0.250 A | 0.400 A |
Supporting protocol for LON: | false |
Supporting protocol for TCP/IP: | false |
Supporting protocol for ASI: | false |
Supporting protocol for PROFIBUS: | false |
Supporting protocol for CAN: | false |
Supporting protocol for INTERBUS: | false |
Supporting protocol for Modbus: | false |
Supporting protocol for Data-Highway: | false |
Supporting protocol for DeviceNet: | false |
Supporting protocol for SUCONET: | false |
Supporting protocol for other bus systems: | false |
External reset possible: | false |
Rail mounting possible: | true |
Rated control supply voltage Us at AC 50HZ: | 0.000 V |
Rated control supply voltage Us at AC 60HZ: | 0.000 V |
Rated control supply voltage Us at DC: | 24.000 V |
Degree of protection (IP): | IP20 |
Supporting protocol for SERCOS: | false |
Supporting protocol for INTERBUS-Safety: | false |
Release class: | CLASS 10 A |
With short-circuit release: | true |
With fuse: | false |
Type of electrical connection of main circuit: | Screw connection |
Type of electrical connection for auxiliary- and control current circuit: | Screw connection |
Supporting protocol for AS-Interface Safety at Work: | false |
Supporting protocol for DeviceNet Safety: | false |
Supporting protocol for EtherNet/IP: | false |
Supporting protocol for Foundation Fieldbus: | false |
Supporting protocol for PROFINET CBA: | false |
Supporting protocol for PROFINET IO: | false |
Supporting protocol for PROFIsafe: | false |
Supporting protocol for SafetyBUS p: | false |
Voltage type for actuating: | DC |
Type of motor starter: | Direct online starter (DOL) |
Rated operation power at AC-3, 230 V, 3-phase: | 0.060 kW |
Rated power, 460 V, 60 Hz, 3-phase: | 0.000 kW |
Rated power, 575 V, 60 Hz, 3-phase: | 0.000 kW |
Rated operation current at AC-3, 400 V: | 0.400 A |
Ambient temperature, upper operating limit: | 55.000 °C |
Temperature compensated overload protection: | true |
Rated conditional short-circuit current, type 2, 400 V: | 50000.000 A |
Rated conditional short-circuit current, type 2, 230 V: | 50000.000 A |
Rated conditional short-circuit current, type 1, 480 Y/277 V: | 0.000 A |
Rated conditional short-circuit current, type 1, 600 Y/347 V: | 0.000 A |
Degree of protection (NEMA): | Other |
Coordination class according to IEC 60947-4-3: | Class 2 |