Maximum Load Current = 5 A Mounting Type = DIN Rail Maximum Load Voltage = 280 V Minimum Load Voltage = 12 V Maximum Control Voltage = 15 V Switching Type = Zero Crossing Control Voltage Range = 3 ...
Maximum Load Current = 25 A rms Mounting Type = Panel Mount Maximum Load Voltage = 530 V ac Minimum Load Voltage = 48 V ac Minimum Control Voltage = 4 V dc Switching Type = Zero Cross Control Volta...
Maximum Load Current = 50 A Mounting Type = Panel Mount Maximum Load Voltage = 660 V ac Minimum Load Voltage = 48 V ac Maximum Control Voltage = 48 V dc, 280 V acV ac/dc Switching Type = Zero Cross...
Derating will limit the maximum load current at temperatures above 25 °C. UL; CSA; VDE. Integral heatsink and DIN rail clip included. CMRD/A Series, 240/480/600Vac, ac O/P SSRs. Zero Voltage Switch...
Maximum Load Current = 25 A rms Mounting Type = PCB Mount Maximum Load Voltage = 280 V rms Minimum Load Voltage = 12 V rms Minimum Control Voltage = 3 V Switching Type = Zero Cross Control Voltage ...
Maximum Load Current = 120 A Mounting Type = Panel Mount Maximum Load Voltage = 72 V dc Minimum Load Voltage = 7 V dc Minimum Control Voltage = 4.5 V dc Switching Type = DC Control Voltage Range = ...
Maximum Load Current = 5 A Mounting Type = PCB Mount Maximum Load Voltage = 530 V ac Minimum Load Voltage = 48 V ac Minimum Control Voltage = 4 V dc Switching Type = Zero Cross Control Voltage Rang...
Derating will limit the maximum load current at temperatures above 25 °C. UL; CSA; VDE. Integral heatsink and DIN rail clip included. CMRD/A Series, 240/480/600Vac, ac O/P SSRs. Zero Voltage Switch...
Maximum Load Current = 25 A rms Mounting Type = Panel Mount Maximum Load Voltage = 280 V dc Minimum Load Voltage = 24 V dc Minimum Control Voltage = 4 V dc Switching Type = Zero Cross Control Volta...
CX241 Series SIL SSR, 1.5A at 280Vac. These Crydom CX241 Series of SSRs have a rating of 1.5 A at 280 Vac with DC control and SCR output. Zero-cross switching where stated otherwise random-fire
Derating will limit the maximum load current at temperatures above 25 °C. UL, CSA, VDE. Heat sink not included. For load current de-rating and heat sink details see manufacturers datasheet. Crydom ...
LS Series - SIL SSR 12A at 280Vac. These Crydom LS series SIL SSRs have a metal baseplate design for direct attachment of external heat sink to achieve maximum current ratings. The LS series SCR ou...
CX241 Series SIL SSR, 1.5A at 280Vac. These Crydom CX241 Series of SSRs have a rating of 1.5 A at 280 Vac with DC control and SCR output. Zero-cross switching where stated otherwise random-fire
Derating will limit the maximum load current at temperatures above 25 °C. UL recognised component for Canada and US, VDE. Heat sink not included. For load current de-rating and heat sink details se...
Derating will limit the maximum load current at temperatures above 25 °C. UL, CSA, VDE. Heat sink not included. For load current de-rating and heat sink details see manufacturers datasheet. Crydom ...