Test lead with IEC connector, neck strap, user manual. RS PRO IRT1900 Digital RCD Tester, 500 mA Trip. RS PRO IRT1900 is a great value digital RCD (Residual Current Device) tester which incorporate...
Test Equipment Type = Digital RCD Tester Maximum Voltage Measurement = 230V RCD Test Type = General, Selective PSC Display = No RCD Test Current = 10/30/100/500/1000mA Safety Category = CAT III 600 VV
Loop Impedance Test Type = Phase to Earth Maximum Voltage Measurement = 400V ac RCD Test Type = Tripping test (pulse) Best Loop Test Accuracy = ±(3 % L+ 5 D) RCD Test Current = 30mA Non-Trip Loop T...
RCDT320 differential circuit breaker tester. Differential circuit breaker tester that meets the requirements of NFC 15-100, EN6557-3 and IEC 61010 for testing low-voltage electrical wiring. 0 ° or ...
Instructions, Mains plug test leads, 8 AA alkaline batteries, neck strap. RS is an authorised Megger distributor. Purchased though RS this product is eligible for the Megger extended 3 Year warrant...
Loop Impedance Test Type = 2 Wire Maximum Voltage Measurement = 300V ac RCD Test Type = AC Selective, DC Selective RCD Test Current = 500mA Safety Category = CAT III 300V Display Type = LCD Battery...
Loop Impedance Test Type = 2 Wire Maximum Voltage Measurement = 440V RCD Test Type = AC Selective PSC Display = No Best Loop Test Accuracy = ±10% RCD Test Current = 4A Non-Trip Loop Test = Yes Safe...
Test Equipment Type = Combined Loop & RCD Tester Maximum Voltage Measurement = 440V RCD Test Type = AC Selective Best Loop Test Accuracy = ±10% RCD Test Current = 4A Non-Trip Loop Test = Yes Safety...
Test lead set with crocodile clips, mains socket test lead, 8 AA alkaline batteries, hard carry case and instructions. RS is an authorised Megger distributor. Purchased though RS this product is el...
durable hard carry case; BS1363 mains socket test lead; 8 x AA alkaline batteries; instructions. RS is an authorised Megger distributor. Purchased though RS this product is eligible for the Megger ...
Loop Impedance Test Type = 2 Wire Maximum Voltage Measurement = 500V RCD Test Type = AC Selective, DC Selective PSC Display = Yes Best Loop Test Accuracy = ±2% RCD Test Current = 10 mA, 30 mA, 100 ...
Durable hard carry case, instructions, 3 wire test lead with crocodile clips, BS1363 mains socket test lead, 8 off AA alkaline batteries. RS is an authorised Megger distributor. Purchased though RS...
The Multimetrix VT11 is the wall plug tester and the rated voltage required for the device is the 230V. It have differential sensitivity up to 30 mA.Temperature range is 0 to 40 °C Relative humidit...